DQRID : D081218.2
Start DateStart TimeEnd DateEnd Time
10/28/2008220002/04/20092045
Subject:
SGP/SWATS/E10 - Soil temperature irregular, 25cm W
DataStreams:sgpswatsE10.b1
Description:
The 25 cm W sensor was demonstrating temporal irregularities and were noisy at times.  
These irregularities consisted of dips and increases of around 2-4 C that typically started 
around 14:00 or 15:00 GMT on most days. On other days the values appeared somewhat noisy 
throughout the day. In both cases, the temporal changes did not compare well with the 
other sensors installed at E10.

A broken wire was repaired for 25cm W sensor.
Measurements:sgpswatsE10.b1:
  • Soil Temperature, West Profile(tsoil_W)


Back To Table of Contents

DQRID : D081218.3
Start DateStart TimeEnd DateEnd Time
09/01/2008000002/26/20091545
Subject:
SGP/SWATS/E27 - Incorrect soil temperature measurements
DataStreams:sgpswatsE27.b1
Description:
All of the tsoil measurements at this EF appear noisy and erratic at times, impacting all 
sensors and both profiles.
Measurements:sgpswatsE27.b1:
  • Soil Temperature, East Profile(tsoil_E)
  • Soil Temperature, West Profile(tsoil_W)


Back To Table of Contents

DQRID : D090320.1
Start DateStart TimeEnd DateEnd Time
12/12/2008000001/15/20091800
Subject:
SGP/SWATS/E19 - Incorrect soil, 35cm E
DataStreams:sgpswatsE19.b1
Description:
The tsoil measurements from the 35 cm E sensor at this site are slightly irregular and too 
noisy at times.
Measurements:sgpswatsE19.b1:
  • Soil Temperature, East Profile(tsoil_E)


Back To Table of Contents