TITLE: Radiation ARM Infrared Temperature (IRT) [JOSS] CONTACTS: Vic Morris Pacific Northwest National Laboratory P.O. Box 999 Richland, WA 99352 Phone: (509) 372-6144 Fax: (509) 372-6168 Email: victor.morris@pnl.gov 1.0 DATA SET OVERVIEW This data set contains 60 second resolution surface infrared temperature from 10 and 25 m downward looking pyrometer. In addition the 25 m data includes upwelling longwave and shortwave hemispheric irradiances. Both the 10 and 25 m IRT sensors are located at the ARM SGP Central Facility. This data set covers the period from 13 May to 25 June 2002. The data are in netCDF format. 2.0 INSTRUMENT DESCRIPTION 2.1 Instrumentation Full information on the ARM SIRS instrumentation is available from ARM at: http://www.arm.gov/docs/instruments/static/irt.html 2.2 Station Locations Site Elev (m) Lat. Long. Sfc Type. ---------------------------------------------------------- Central Facility 318 36.605 N 97.485 W Pasture 3.0 DATA COLLECTION AND PROCESSING Full information on the ARM SIRS data collection and processing is available from ARM at: http://www.arm.gov/docs/instruments/static/irt.html General information on ARM data quality is available from ARM at: http://dq.arm.gov/cgi-bin/dqmenu.pl UCAR/JOSS conducted no processing or quality control on these data. 4.0 DATA FORMAT AND FILE NAMING 4.1 Data Format These data are in network Common Data Form (netCDF) format. For information on netCDF see: http://www.unidata.ucar.edu/packages/netcdf/index.html 4.2 File Naming Conventions The data file names have the following format: sgpirt10mC1.a1.20020622.000000.cdf where: sgpirt10m is the data type (10 m IRT) C1 represents the facility id (here ARM SGP central facility) a1 represents the data level 2002 - four digit year 06 - two digit month 22 - two digit day 00 - two digit hour 00 - two digit minute 00 - two digit second cdf - netCDF format extention 5.0 DATA REMARKS None. 6.0 REFERNCES None.