TITLE: POC_PN_HLY-02-03 PI: Dr. H. Rodger Harvey Chesapeake Biological Laboratory University of Maryland Center for Environmental Science P.O. Box 38 Solomons, MD 20688 Phone: 410-326-7206 Fax: 410-326-7341 Email: harvey@cbl.umces.edu Website: http://mogel.cbl.umces.edu FUNDING SOURCE AND GRANT NUMBER: NSF: OPP-0125316 DATA SET OVERVIEW: This data set represents measurements of POC and PN for water column suspended particles collected during the 2002 HLY-02-03 Process Cruise. Particulates were collected by filtration onto pre-combusted (450¡C for 4hrs) 25mm Whatman GF/F filters. The filters were stored frozen until analysis. Filters were dried at 40C for 24 hours, then carbonates were removed by vapor phase acidification with HCl. Samples were analyzed at the Nutrient Analytical Services Laboratory at the Chesapeake Biological Laboratory, University of Maryland Center for Environmental Science, Solomons, Maryland, using an Exeter Analytical, Inc., CE-440 Elemental Analyzer. This data set consists of an excel workbook with one spreadsheets. The worksheet contains the number and name of the station, latitude, longitude, water depth of sample, POC (ug/L), PN (ug/L), and POC:PN based on elemental ratios. Comments for the data are located in the header. Stations are highlighted with alternate gray and white for ease of viewing.