DQR ID | Subject | Data Streams Affected |
---|---|---|
D030602.5 | SGP/TWR/C1 - C1 TWR 10X Data Incorrect During Power Cycling | sgp1twr10xC1.a1, sgp1twr10xC1.b1, sgp30twr10xC1.a1, sgp30twr10xC1.b1 |
D030912.1 | SGP/TWR/C1 - Southeast 25 and 60 m T/RH/VP Incorrect | sgp1twr10xC1.a1, sgp1twr10xC1.b1, sgp30twr10xC1.a1, sgp30twr10xC1.b1 |
D030912.2 | SGP/TWR/C1 - Southeast 25 and 60 m T/RH/VP Incorrect | sgp1twr10xC1.a1, sgp1twr10xC1.b1, sgp30twr10xC1.a1, sgp30twr10xC1.b1 |
D030912.4 | SGP/TWR/C1 - Southeast 25 and 60 m T/RH/VP Incorrect | sgp1twr10xC1.a1, sgp1twr10xC1.b1, sgp30twr10xC1.a1, sgp30twr10xC1.b1 |
D040304.30 | SGP/TWR/C1 - Southeast Side RH Too Large | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/16/2003 | 2053 | 05/16/2003 | 2054 |
Subject: | SGP/TWR/C1 - C1 TWR 10X Data Incorrect During Power Cycling |
DataStreams: | sgp1twr10xC1.a1, sgp1twr10xC1.b1, sgp30twr10xC1.a1, sgp30twr10xC1.b1 |
Description: | Data was incorrect during cycling of power for the MFR. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.a1:
sgp1twr10xC1.a1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/2003 | 1837 | 08/05/2003 | 1914 |
Subject: | SGP/TWR/C1 - Southeast 25 and 60 m T/RH/VP Incorrect |
DataStreams: | sgp1twr10xC1.a1, sgp1twr10xC1.b1, sgp30twr10xC1.a1, sgp30twr10xC1.b1 |
Description: | The SE elevator system that the T/RH sensors are on was down for service of another instrument system. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.a1:
sgp1twr10xC1.a1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/14/2003 | 1445 | 08/14/2003 | 1521 |
08/14/2003 | 192 | 08/14/2003 | 1915 |
08/14/2003 | 1924 | 08/14/2003 | 1937 |
08/15/2003 | 1344 | 08/15/2003 | 1945 |
Subject: | SGP/TWR/C1 - Southeast 25 and 60 m T/RH/VP Incorrect |
DataStreams: | sgp1twr10xC1.a1, sgp1twr10xC1.b1, sgp30twr10xC1.a1, sgp30twr10xC1.b1 |
Description: | The SE elevator system that the T/RH sensors are on was down for service of the PGS system and tower maintenance on 14 Aug and for T/RH calibrations/checks on 15 Aug. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.a1:
sgp1twr10xC1.a1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/19/2003 | 1416 | 08/19/2003 | 164 |
Subject: | SGP/TWR/C1 - Southeast 25 and 60 m T/RH/VP Incorrect |
DataStreams: | sgp1twr10xC1.a1, sgp1twr10xC1.b1, sgp30twr10xC1.a1, sgp30twr10xC1.b1 |
Description: | The SE elevator system that the T/RH sensors are on was down to service the MFR. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.a1:
sgp1twr10xC1.a1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/15/2003 | 1345 | 02/10/2004 | 2310 |
Subject: | SGP/TWR/C1 - Southeast Side RH Too Large |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The T/RH probes installed on the 25 m and 60 m levels of the southeast side of the tower on 8/15/03 gave RH readings that were too large for RH above 65%. The difference between the west and southeast side RH was within the combined accuracies of the sensors up to about 80% RH. Above 80% RH the southeast side RH was much larger, with the difference increasing to 10% larger (or more) at 100% RH. The vapor pressure from the southeast side (calculated with RH) was also too large. The probes were replaced on 2/10/04 and the two sides of the tower now agree fairly well, with RH not exceeding 100% during saturation. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|