Data Quality Reports for Session: 95369 User: sloehrer Completed: 09/15/2005


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050422.9SGP/SMOS/E27 - Wind direction offsetsgp1smosE27.b1, sgp30smosE27.b1
D050614.2SGP/SMOS/E6 - RH Sensor failuresgp1smosE6.b1, sgp30smosE6.b1, sgp1440smosE6.b1
D050817.1SGP/SMOS/E20 - Sensor failuresgp1smosE20.b1, sgp30smosE20.b1


DQRID : D050422.9
Start DateStart TimeEnd DateEnd Time
10/13/200300Open Ended00
10/13/20030005/11/20051615
Subject:
SGP/SMOS/E27 - Wind direction offset
DataStreams:sgp1smosE27.b1, sgp30smosE27.b1
Description:
When the SGP.E27 SMOS tower was installed it was not aligned
properly resulting in a 7 degree offset.
Measurements:sgp1smosE27.b1:
  • Unit Vector Wind Direction(wdir)

sgp30smosE27.b1:
  • Unit Vector Wind Direction(wdir)


Back To Table of Contents

DQRID : D050614.2
Start DateStart TimeEnd DateEnd Time
06/04/20052006/30/20051545
Subject:
SGP/SMOS/E6 - RH Sensor failure
DataStreams:sgp1smosE6.b1, sgp30smosE6.b1, sgp1440smosE6.b1
Description:
The RH readings on the SMOS dropped to zero or became very noisy during rain or moist 
conditions.  The sensor was replaced.
Measurements:sgp1smosE6.b1:
  • Vapor Pressure (kiloPascals)(vap_pres)
  • Relative humidity scaled, by total column amount from MWR(rh)

sgp30smosE6.b1:
  • Standard deviation of Vapor Pressure(sd_vap_pres)
  • Standard deviation of Relative Humidity(sd_rh)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Vapor Pressure (kiloPascals)(vap_pres)

sgp1440smosE6.b1:
  • Time of Minimum Relative Humidity(time_min_rh)
  • Time of Minimum Vapor Pressure(time_min_vap_pres)
  • Minimum Relative Humidity(min_rh)
  • Time of Maximum Relative Humidity(time_max_rh)
  • Maximum Relative Humidity(max_rh)
  • Time of Maximum Vapor Pressure(time_max_vap_pres)
  • Minimum Vapor Pressure(min_vap_pres)
  • Maximum Vapor Pressure(max_vap_pres)


Back To Table of Contents

DQRID : D050817.1
Start DateStart TimeEnd DateEnd Time
08/12/2005165108/17/20051921
Subject:
SGP/SMOS/E20 - Sensor failure
DataStreams:sgp1smosE20.b1, sgp30smosE20.b1
Description:
Wind direction values were nearly constant around a value of 15 degrees.  Problem was 
caused by a lightning strike which damaged the sensor.
Measurements:sgp1smosE20.b1:
  • Standard Deviation of wind direction(sd_deg)
  • Unit Vector Wind Direction(wdir)

sgp30smosE20.b1:
  • Unit Vector Wind Direction(wdir)
  • Standard Deviation of wind direction(sd_deg)


Back To Table of Contents



END OF DATA